| Air Conditioning | The air conditioning system on this machine contains the fluorinated greenhouse gas refrigerant R134a (Global Warming Potential = 1430). The system contains 1.9 kg of refrigerant which has a CO2 equivalent of 2.717 metric tonnes. |
|---|
| Capacity - General Purpose | 4 cu yd |
|---|---|
| Capacity - Slag | 4 cu yd |
| Width - Slag | 112.00 in (284.48 cm) |
| Bucket Height - Carry Position | 19.00 in (48.26 cm) |
|---|---|
| Carry Position Approach Angle | 15 degrees |
| Clearance At Full Lift Height And 45 Degrees Dump* | 116.20 in (295.15 cm) |
| Digging Depth* | 6.20 in (15.75 cm) |
| Grading Angle | 85 degrees |
| Ground Clearance | 1.55 ft (0.47 m) |
| Height - Bucket Hinge Pin | 166.10 in (421.89 cm) |
| Height - Top Of Stack | 120.80 in (306.83 cm) |
| Height To Top Of The Seat With Headrest | 117.60 in (298.70 cm) |
| Length - Front Of Track | 209.60 in (532.38 cm) |
| Machine Height - Top Of Cab | 140.00 in (355.60 cm) |
| Maximum Rollback - Ground/Carry Position | 43 degrees/47 degrees |
| Maximum Rollback/Dump - Fully Raised | 59 degrees/49 degrees |
| Note | *With General Purpose bucket Performance with heavy duty teeth. Dimensions vary with bucket. Refer to Operating Specifications chart.<ul><li>Machine Height to Top of Cab is with Steel Mill plate.</li></ul> |
| Overall Machine Height - Bucket Fully Raised | 226.50 in (575.31 cm) |
| Overall Machine Length* | 298.40 in (757.94 cm) |
| Overall Machine Width With Slag Bucket: Steel Mill Tracks - 500 Mm (19.7 In) | 116.50 in (295.91 cm) |
| Overall Machine Width Without Bucket: Steel Mill Tracks - 500 Mm (19.7 In) Shoes | 107.90 in (274.07 cm) |
| Ramp Angle | 29 degrees |
| Reach At Full Lift Height And 45 Degrees Dump* | 53.80 in (136.65 cm) |
| Emissions | U.S. EPA Tier 4 Final/EU Stage IV/Korea Tier 4 |
|---|---|
| Engine Model | Cat C9.3 ACERT |
| Engine Power - Maximum - Iso 14396 | 306.00 hp (228.19 kw) |
| Engine Power - Maximum - Iso 14396 (Din) | 310.00 hp (231.17 kw) |
| Engine Power - Maximum - Sae J1995 | 310.00 hp (231.17 kw) |
| Flywheel Power | 275.00 hp (205.07 kw) |
| Net Power (Rated) - Iso 9249/Sae J1349 | 275.00 hp (205.07 kw) |
| Net Power (Rated) - Iso 9249/Sae J1349 (Din) | 278.00 hp (207.31 kw) |
| Note (1) | Engine ratings at 1,800 rpm. |
| Note (2) | No derating required up to 2164 m (7,200 ft) altitude. |
| Note (3) | All nonroad Tier 4 Final, Stage IV and Korea Tier 4 diesel engines are required to use only Ultra Low Sulfur Diesel (ULSD) with 15 ppm (mg/kg) of sulfur or less, or up to B20 biodiesel blended with ULSD. B20 should meet ASTM D7467 specification (biodiesel blend stock should meet Cat biodiesel spec, ASTM D6751 or EN 14214). Cat DEO-ULS or oils that meet the Cat ECF-3, API CJ-4, and ACEA E9 specification are required. Consult your OMM for further machine specific fuel recommendations. |
| Note (4) | Diesel Exhaust Fluid (DEF) used in Cat Selective Catalytic Reduction (SCR) systems must meet the requirements outlined in the International Organization for Standardization (ISO) standard 22241. |
| Operating Weight | 74,293.00 lbs (33,698.78 kg) |
|---|
| Cooling System | 11.60 gal (43.91 l) |
|---|---|
| Def Tank | 9.20 gal (34.82 l) |
| Fuel Tank | 101.50 gal (384.18 l) |
| Brakes | Brakes meet the standard ISO 10265:2008. |
|---|---|
| Cab - Declared Dynamic Operator Sound Pressure Level | <ul><li>The declared dynamic operator sound pressure level when "ISO 6396:2008" is used to measure the value for an enclosed cab is 75 dB(A). The measurements were conducted at 80% of the maximum engine cooling fan speed. The sound level may vary at different engine cooling fan speeds. The cab was properly installed and maintained. The measurements were conducted with the cab doors and the cab windows closed.</li><li>NOTE: The dynamic operator sound pressure level uncertainty is 2 dB(A).</li></u |
| Cab - Hearing Protection | Hearing protection may be needed when the machine is operated with an open operator station for extended periods, in a noisy environment or with a cab that is not properly maintained. |
| Cab - Labeled Sound Power Level | The guaranteed exterior sound power level (LWA) is measured according to the dynamic test procedures and the conditions that are specified in "ISO 6395:2008" [111 dB(A)]. The measurements were conducted at 80% of the maximum engine cooling fan speed. The sound level may vary at different engine cooling fan speeds. |
| Fops | FOPS (Falling Object Protective Structure) meets ISO 3449-2005 Level II. |
| Rops | ROPS (Rollover Protective Structure) offered by Caterpillar for the machine meets ROPS criteria ISO 3471:2008. |
| Sound Level Information (Eu) | <ul><li>Sound Level Information for Machines in European Union Countries and in Countries that Adopt the "EU Directives": The declared dynamic operator sound pressure level when "ISO 6396:2008" is used to measure the value for an enclosed cab is 75 dB(A). The measurements were conducted at 80 percent of the maximum engine cooling fan speed. The sound level may vary at different engine cooling fan speeds. The cab was properly installed and maintained. The measurements were conducted with the cab |
| Ground Contact Area (Iso 16754:2008): Steel Mill Shoe - 500 Mm (19.7 In) | 5161 in2 |
|---|---|
| Ground Pressure* (Iso 16754:2008): Steel Mill Shoe - 500 Mm (19.7 In) | 14.4 psi |
| Grouser Height - Double Grouser | 1.90 in (4.83 cm) |
| Link Pitch | 8.50 in (21.59 cm) |
| Note | * Calculated using Steel Mill operating weight with Slag Bucket. |
| Number Of Shoes - Each Side | 40 |
| Track Gauge | 7.09 ft (2.16 m) |
| Track On Ground | 115.40 in (293.12 cm) |
| Track Rollers - Each Side | 7 |
| Track Shoe Type | Heavy Duty Sealed and Non Lubricated - Steel Mill, Double Grouser |
| Track Shoe Width - Standard | 19.70 in (50.04 cm) |
| Note | Steel Mill weights are with new slag bucket. |
|---|---|
| Operating Weight - Steel Mill | 74,293.00 lbs (33,698.78 kg) |
| Shipping Weight - Steel Mill | 63,097.00 lbs (28,620.35 kg) |