| Cooling Method | Liquid - Starting 2026 |
|---|---|
| Efficiency | 96% - Starting 2026 |
| Motor Type | Switched Reluctance - Starting 2026 |
| Rated Power (peak, nominal) | 303.00 hp (225.95 kw) - Starting 2026 |
| Rated Torque (peak, nominal = 1,600 equivalent rpm) | 600 N·m/531 N·m (443 lbf-ft/392 lbf-ft) - Starting 2026 |
| Service Interval | 12,000-13,000 hours - Starting 2026 |
| Battery Chemistry | Li-lon - Starting 2026 |
|---|---|
| Battery Cooling Method | Chilled Liquid (Extended Life Coolant) - Starting 2026 |
| Battery Monitoring | With integrated Caterpillar controls systems - Starting 2026 |
| Charging Current, Voltage | 1160A (output), 820VDC - Starting 2026 |
| Charging Method | Ultra Fast Charge Onboard - Starting 2026 |
| Charging Rate | Up to 4C (matched with MEC500 chargers) - Starting 2026 |
| Maximum Charging Rate | 840 kW (two MEC500 chargers) - Starting 2026 |
| Minimum Charging Rate | 500.00 kw (670.50 hp) - Starting 2026 |
| On Board Fast Charging Charge time (0-100%) | Less than 20 minutes (two MEC500 in parallel); Less than 30 minutes (one MEC500) - Starting 2026 |
| Operating Temperature Limits (ambient) | 50° C/–20° C (122° F/-4° F) - Starting 2026 |
| Pack Energy Capacity - Total | 213 kWh - Starting 2026 |
| Pack Voltage - Nominal | 715 V - Starting 2026 |
| 0% Grade - Loaded | 11.20 mph (18.02 kph) - Starting 2026 |
|---|---|
| 0% Grade - Unloaded | 11.20 mph (18.02 kph) - Starting 2026 |
| 10% Grade - Loaded | 5.30 mph (8.53 kph) - Starting 2026 |
| 10% Grade - Unloaded | 6.90 mph (11.10 kph) - Starting 2026 |
| 15% Grade - Loaded | 3.80 mph (6.12 kph) - Starting 2026 |
| 15% Grade - Unloaded | 4.90 mph (7.89 kph) - Starting 2026 |
| 20% Grade - Loaded | 3.00 mph (4.83 kph) - Starting 2026 |
| 20% Grade - Unloaded | 3.90 mph (6.28 kph) - Starting 2026 |
| 5% Grade - Loaded | 9.20 mph (14.81 kph) - Starting 2026 |
| 5% Grade - Unloaded | 11.20 mph (18.02 kph) - Starting 2026 |
| Dump | 3.3 s - Starting 2026 |
|---|---|
| Lower, Empty, Float Down | 2.9 s - Starting 2026 |
| Raise | 6.8 s - Starting 2026 |
| Total Cycle Time | 13.2 s - Starting 2026 |
| Lift Cylinder - Bore | 7.00 in (17.78 cm) - Starting 2026 |
|---|---|
| Lift Cylinder - Stroke | 33.00 in (83.82 cm) - Starting 2026 |
| Lift/Tilt System - Circuit | Electro – Hydraulic, Positive Flow Control, Flow Sharing - Starting 2026 |
| Lift/Tilt System - Pump | Variable Flow Piston/Hydraulic Load Sense - Starting 2026 |
| Maximum Flow | 78.50 gpm (297.12 lpm) - Starting 2026 |
| Relief Valve Setting - Main | 4932 psi - Starting 2026 |
| Tilt Cylinder - Bore | 8.00 in (20.32 cm) - Starting 2026 |
| Tilt Cylinder - Stroke | 22.00 in (55.88 cm) - Starting 2026 |
| Breakout Force - Lift and Tilt | 53,330.00 lbs (24,190.11 kg) - Starting 2026 |
|---|---|
| Bucket Capacities | 5.7-7.5 m³ (7.5-9.8 yd³) - Starting 2026 |
| Nominal Payload Capacity | 33,069.00 lbs (14,999.86 kg) - Starting 2026 |
| Operating Mass | 107,460.00 lbs (48,743.10 kg) - Starting 2026 |
| Ride Control | Yes - Starting 2026 |
| Shipping Weight | 114,460.00 lbs (51,918.25 kg) - Starting 2026 |
| Static Tipping Load - Full Turn - Lift Arms Horizontal | 89,600.00 lbs (40,641.93 kg) - Starting 2026 |
| Static Tipping Load - Straight Ahead - Lift Arms Horizontal | 108,500.00 lbs (49,214.83 kg) - Starting 2026 |
| Component Ratings | IP67, IP69K - Starting 2026 |
|---|---|
| Cooling Method | Liquid (coolant) - Starting 2026 |
| Inverter Rating | 350A (nominal DC), 715VDC - Starting 2026 |
| Service Interval | 12,000-13,000 hours - Starting 2026 |
| Ability of Regenerative Braking | Yes - Starting 2026 |
|---|---|
| Cooling Method | Liquid - Starting 2026 |
| Efficiency | 95% - Starting 2026 |
| Motor Type | Switched Reluctance - Starting 2026 |
| Rated Power - Nominal | 295.00 hp (219.99 kw) - Starting 2026 |
| Rated Power - Peak | 335.00 hp (249.81 kw) - Starting 2026 |
| Rated Torque (peak, nominal = @ 12 km/h [7.5 mph] and nominal power) | 3200 N·m/660 N·m (2360 lbf-ft/443 lbf-ft) - Starting 2026 |
| Service Interval | 12,000-13,000 hours - Starting 2026 |