| General Specifications | |
| Aspiration (Since 2006) | ATAAC |
| Cylinder Configuration (Since 2006) | I6 |
| Diesel Industrial Power Range (Since 2006) | 425 - 575 hp (317 - 429 kw) |
| Displacement (Since 2006) | 893 cu in (14,634 cu cm) |
| Emissions Compliance Mark (Since 2010) | X |
| Emissions Compliance Mark - Dry Manifolds (E Level) (Since 2006) | X |
| Emissions Compliance Mark - Wet Manifolds (Since 2006) | X |
| Fracturing / Acidizing / Cementing Power (Since 2010) | 575 bhp (428 bkW) |
| Fracturing / Acidizing / Cementing Power (Since 2010) | 500 bhp (373 bkW) |
| Fracturing / Acidizing / Cementing Power (Since 2012) | 575 bhp (428 bkW) |
| Fracturing / Acidizing / Cementing Power - Dry Manifolds (E Level) (Since 2006) | 575 bhp (428 bkW) |
| Fracturing / Acidizing / Cementing Power - Wet Manifolds (Since 2006) | 500 bhp (373 bkW) |
| Fuel System (Since 2006) | EUI |
| Industrial Power - IND A (Since 2006) | 425 bhp (317 bkW) |
| Industrial Power - IND B (Since 2006) | 450 bhp (336 bkW) |
| Industrial Power - IND C (Since 2006) | 525 bhp (392 bkW) |
| Industrial Power - IND C (Since 2006) | 475 bhp (354 bkW) |
| Industrial Power - IND C (Since 2006) | 500 bhp (373 bkW) |
| Industrial Power - IND C (Since 2006) | 525 bhp (391 bkW) |
| Industrial Power - IND D (Since 2006) | 565 bhp (421 bkW) |
| Industrial Power - IND D (Since 2006) | 475 bhp (354 bkW) |
| Industrial Power - IND D (Since 2006) | 515 bhp (384 bkW) |
| Industrial Power - IND E (Since 2006) | 575 bhp (429 bkW) |
| Industrial Power - IND E (Since 2006) | 475 bhp (354 bkW) |
| Industrial Power - IND E (Since 2006) | 525 bhp (392 bkW) |
| Industrial Rated Speed - IND A (Since 2006) | 1,800 - 2,100 rpm |
| Industrial Rated Speed - IND B (Since 2006) | 1,800 - 2,100 rpm |
| Industrial Rated Speed - IND C (Since 2006) | 2,100 rpm |
| Industrial Rated Speed - IND C (Since 2006) | 1,800 - 2,100 rpm |
| Industrial Rated Speed - IND D (Since 2006) | 1,800 - 2,100 rpm |
| Industrial Rated Speed - IND D (Since 2006) | 2,100 rpm |
| Industrial Rated Speed - IND E (Since 2006) | 1,800 - 2,100 rpm |
| Industrial Rated Speed - IND E (Since 2006) | 2,100 rpm |
| Locomotive Traction Power - High Rating (Since 2006) | 575 hp (429 kw) |
| Locomotive Traction Power - Low Rating (Since 2006) | 425 hp (317 kw) |
| Locomotive Traction Rated Speed Range (Since 2006) | 1,800 - 2,100 rpm |
| Maintenance of Way Power - High Rating (Since 2006) | 575 hp (429 kw) |
| Maintenance of Way Power - Low Rating (Since 2006) | 425 hp (317 kw) |
| Maintenance of Way Rated Speed Range (Since 2006) | 1,800 - 2,100 rpm |
| Prime Output - 60 Hz (Since 2015) | 455 ekW |
| Prime Output - 60 Hz (Since 2015) | 320 ekW |
| Prime Output - 60 Hz (Since 2015) | 365 ekW |
| Prime Output - 60 Hz (Since 2015) | 410 ekW |
| Prime Output - 60 Hz (Since 2016) | 365 ekW |
| Prime Output - 60 Hz (Since 2016) | 320 ekW |
| Prime Output - 60 Hz (Since 2016) | 455 ekW |
| Prime Output - 60 Hz (Since 2017) | 365 ekW |
| Prime Output - 60 Hz (Since 2017) | 320 ekW |
| Prime Output - 60 Hz (Since 2017) | 410 ekW |
| Prime Output - 60 Hz (Since 2018) | 365 ekW |
| Prime Output - 60 Hz (Since 2018) | 320 ekW |
| Prime Output - 60 Hz (Since 2018) | 455 ekW |
| Prime Output - 60 Hz (Since 2019) | 320 ekW |
| Prime Output - 60 Hz (Since 2019) | 455 ekW |
| Prime Output - 60 Hz (Since 2019) | 365 ekW |
| Prime Output - 60 Hz (Since 2019) | 410 ekW |
| Rated Speed (Since 2010) | 2,100 rpm |
| Rated Speed - Dry Manifolds (E Level) (Since 2006) | 2,100 rpm |
| Rated Speed - Wet Manifolds (Since 2006) | 2,100 rpm |
| Standby Output - 60 Hz (Since 2015) | 350 ekW |
| Standby Output - 60 Hz (Since 2015) | 500 ekW |
| Standby Output - 60 Hz (Since 2015) | 400 ekW |
| Standby Output - 60 Hz (Since 2015) | 450 ekW |
| Standby Output - 60 Hz (Since 2016) | 500 ekW |
| Standby Output - 60 Hz (Since 2016) | 450 ekW |
| Standby Output - 60 Hz (Since 2016) | 350 ekW |
| Standby Output - 60 Hz (Since 2016) | 400 ekW |
| Standby Output - 60 Hz (Since 2017) | 350 ekW |
| Standby Output - 60 Hz (Since 2017) | 500 ekW |
| Standby Output - 60 Hz (Since 2017) | 450 ekW |
| Standby Output - 60 Hz (Since 2017) | 400 ekW |
| Standby Output - 60 Hz (Since 2018) | 350 ekW |
| Standby Output - 60 Hz (Since 2018) | 450 ekW |
| Standby Output - 60 Hz (Since 2018) | 500 ekW |
| Standby Output - 60 Hz (Since 2019) | 350 ekW |
| Standby Output - 60 Hz (Since 2019) | 400 ekW |
| Standby Output - 60 Hz (Since 2019) | 450 ekW |