Construction Equipment Guide
470 Maryland Drive
Fort Washington, PA 19034
800-523-2200
For Sale: $62,500.00 USD
Apply for Financing| Hours: | 418 |
| Serial Number: | C9E00316 |
| Machine Location: | INDIANAPOLIS, IN |
| More Information: | https://catused.com/cu/10293835 |
Supplied by HeavyEquipmentData.com →
| General Specifications | |
| Aspiration (Since 2006) | ATAAC |
| Aspiration (Since 2006) | DITA |
| Aspiration (Since 2012) | DIT |
| Aspiration (Since 2012) | DITA |
| Aspiration (Since 2013) | DIT |
| Aspiration (Since 2015) | DITTA |
| Aspiration (Since 2016) | DIT |
| Aspiration (Since 2016) | DITTA |
| Cylinder Configuration (Since 2006) | I6 |
| Diesel Industrial Power Range (Since 2006) | 275 - 350 hp (205 - 261 kw) |
| Displacement (Since 2006) | 537 cu in (8,800 cu cm) |
| Fuel System (Since 2006) | HEUI |
| Generator Output - 50 Hz at 1500 rpm (Since 2010) | 150 - 200 ekW |
| Generator Output - 50 Hz at 1500 rpm (Since 2012) | 142 - 200 ekW |
| Generator Output - 60 Hz at 1800 rpm (Since 2010) | 175 - 250 ekW |
| Generator Output - 60 Hz at 1800 rpm (Since 2012) | 163 - 250 ekW |
| Industrial Power - IND A (Since 2006) | 275 bhp (205 bkW) |
| Industrial Power - IND B (Since 2006) | 300 bhp (224 bkW) |
| Industrial Power - IND C (Since 2006) | 350 bhp (261 bkW) |
| Industrial Power - IND C (Since 2006) | 335 bhp (250 bkW) |
| Industrial Power - IND C (Since 2006) | 325 bhp (242 bkW) |
| Industrial Power - IND C (Since 2006) | 300 bhp (224 bkW) |
| Industrial Power - IND C (Since 2006) | 275 bhp (205 bkW) |
| Industrial Rated Speed - IND A (Since 2006) | 1,800 - 2,200 rpm |
| Industrial Rated Speed - IND B (Since 2006) | 1,800 - 2,200 rpm |
| Industrial Rated Speed - IND C (Since 2006) | 2,200 rpm |
| Industrial Rated Speed - IND C (Since 2006) | 1,800 - 2,200 rpm |
| Locomotive Traction Power - High Rating (Since 2006) | 335 hp (250 kw) |
| Locomotive Traction Power - Low Rating (Since 2006) | 275 hp (205 kw) |
| Locomotive Traction Rated Speed Range (Since 2006) | 1,800 - 2,200 rpm |
| Maintenance of Way Power - High Rating (Since 2006) | 350 hp (261 kw) |
| Maintenance of Way Power - Low Rating (Since 2006) | 275 hp (205 kw) |
| Maintenance of Way Rated Speed Range (Since 2006) | 1,800 - 2,200 rpm |
| Marine Generator Output - 50 Hz at 1500 rpm (Since 2006) | 150 - 200 ekW |
| Marine Generator Output - 60 Hz at 1800 rpm (Since 2006) | 175 - 250 ekW |
| Marine Power Range (Since 2006) | 503 hp (375 kw) |
| Marine Propulsion Power Range (Since 2006) | 503 bhp (375 bkW) |
| Prime Output - 60 Hz (Since 2015) | 180 ekW |
| Prime Output - 60 Hz (Since 2015) | 275 ekW |
| Prime Output - 60 Hz (Since 2015) | 225 ekW |
| Prime Output - 60 Hz (Since 2016) | 180 ekW |
| Prime Output - 60 Hz (Since 2016) | 225 ekW |
| Prime Output - 60 Hz (Since 2016) | 275 ekW |
| Prime Output - 60 Hz (Since 2017) | 225 ekW |
| Prime Output - 60 Hz (Since 2017) | 180 ekW |
| Prime Output - 60 Hz (Since 2018) | 275 ekW |
| Prime Output - 60 Hz (Since 2018) | 225 ekW |
| Prime Output - 60 Hz (Since 2018) | 180 ekW |
| Prime Output - 60 Hz (Since 2019) | 275 ekW |
| Prime Output - 60 Hz (Since 2019) | 225 ekW |
| Prime Output - 60 Hz (Since 2019) | 180 ekW |
| Standby Output - 60 Hz (Since 2015) | 200 ekW |
| Standby Output - 60 Hz (Since 2015) | 250 ekW |
| Standby Output - 60 Hz (Since 2015) | 300 ekW |
| Standby Output - 60 Hz (Since 2016) | 250 ekW |
| Standby Output - 60 Hz (Since 2016) | 200 ekW |
| Standby Output - 60 Hz (Since 2017) | 250 ekW |
| Standby Output - 60 Hz (Since 2017) | 300 ekW |
| Standby Output - 60 Hz (Since 2017) | 200 ekW |
| Standby Output - 60 Hz (Since 2018) | 250 ekW |
| Standby Output - 60 Hz (Since 2018) | 300 ekW |
| Standby Output - 60 Hz (Since 2018) | 200 ekW |
| Standby Output - 60 Hz (Since 2019) | 250 ekW |
| Standby Output - 60 Hz (Since 2019) | 300 ekW |